Triaxial accelerometers are designed with three orthogonal sensing elements to enable simultaneous multi-axis measurements (x-, y-, and z-axis). Smaller units minimize mass loading effects and permit installation into confined areas. A unit with a tapped hole in its base may be secured with a screw passing through the object under test to aid in axis alignment, or may be stud-mounted to a separate adhesive mounting base.
These units typically feature a 4-pin electrical connector (for a single cable hook-up) or an integral 4-conductor cable. Types include High Temperature, Miniature, General Purpose, Modal Array, Shock, Seat Pad, or Filtered accelerometers. See accessories for additional mounting equipment or calibration notes for information on calibration. Contact us for detailed selection assistance, or for unique requirements not shown.
*Frequency ranges vary across axes, see full specifications below for all frequency ranges
**Frequency ranges specified at ±1 and ±3 dB for 350B50 sensor
***Frequency range specified at ±1 dB for 350A43 sensor. See below for full specifications.
Lightweight ceramic shear design, titanium cased hermetically sealed units that minimize effects of mass loading. Some units available with TEDS (Transducer Electronic Data Sheet) and high temperature options.
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Note: Base model 356B20 is also available and includes a 10ft breakout cable to BNC, model 034K10. Use model 356B20/NC to omit cabling if not required, or order an appropriate length cable separately.
Similar to: B&K 4520-002, Dytran 3023A9, Endevco 65HT-1, B&K 4520-002
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Note: Base model 356A04 is also available and includes a 5ft breakout cable to BNC, model 034G05. Use model 356A04/NC to omit cabling if not required, or order an appropriate length cable separately.
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Note: Base model 356A01 is also available and includes a 5ft breakout cable to BNC, model 034G05. Use model 356A01/NC to omit cabling if not required, or order an appropriate length cable separately.
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: Dytran 3133A1
356B21
High temperature version available full specs
0.4" titanium cube triaxial sensor
±500g range
4 gram mass
5-40 female mounting
8-36 4-pin jack used with 034K cable series
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4520-001, Dytran 3023A1 & 3023A2H, Endevco 65-10 & 65HT-10, Kistler 8766A500B & H8766A500B
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
This range of hermetically sealed 10.5 gram titanium triaxial accelerometers is our most popular style, and covers a wide range of uses. Applications vary widely and include general vibration testing, motor and pump monitoring, design studies, and vibration control. Many units are available with optional TEDS (Transducer Electronic Datasheet) built in to simplify test setup with a TEDS capable DAQ system.
0.815" hex x 0.45" height titanium triaxial sensor
±500g range
15.5 gram mass
Thru-hole mounting simplifies axis and connector orientation
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 039A23- Allen wrench, 5/32" hex 081B60 -Insulated cap screw, 10-32 thd x 5/8" long Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
356A02
High temperature, TEDS, or High temperature + TEDS versions available
(TEDS notes) full specs
0.55"x0.8"x0.55" titanium cube triaxial sensor
±500g range
10.5 gram mass
10-32 female mounting
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4506 & 4506B, Dytran 3093B1 & 3093B1T
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4506 & 4506B, Dytran 3093B1 & 3093B1T
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4506 & 4506B, Dytran 3093B1 & 3093B1T
Suited for traditional experimental modal analysis or operational modal analysis, with tight phase specification vital for global parameter estimation. TEDS enabled units help channel bookkeeping when used with compatible systems.
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A68 - Adhesive mounting base, 0.75" hex x 0.2" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A68 - Adhesive mounting base, 0.75" hex x 0.2" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Adjusted circuitry allows measurement of these units in temperatures to +325°F (163°C) and are used with traditional ICP power systems. Slight low frequency and broadband resolution specifications may be affected.
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A12 - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081B05 - 10-32 to 10-32 mounting stud with shoulder Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4520-001, Dytran 3023A1 & 3023A2H, Endevco 65-10 & 65HT-10, Kistler 8766A500B & H8766A500B
1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 080A - Adhesive mounting base, 0.5" hex x 0.187" thk, 10-32 tapped hole, aluminum w/insulating hardcoat finish 081A90 - 5-40 to 10-32 adaptor stud Calibration - NIST traceable and ISO 17025/A2LA accredited calibration from 10 Hz to upper 5% point (TMS: MCS-A001T or PCB: ACS-1T). See notes on calibration for additional information
Similar to: B&K 4524B-001, Dytran 3263A1, Endevco 66A11, Kistler 8763B500B
Series 350 ICP® mechanically isolated, electrically filtered pyroshock accelerometers are designed to withstand and measure extreme high-level, short-duration transient accelerations. These units are ideal for measuring harsh pyroshock events such as found in metal-to-metal tests, impacts and armor testing, explosive studies, pile driver monitoring, and simulated pyroshock events. High-g shock calibration is included with rental of 350 Series units.
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 080A197 - Through hole mounting adaptor 081A112 - 6-32 thread x 1/2" long insulated cap screw Calibration - NIST traceable and ISO 17025/A2LA accredited calibration for high G shock using Hopkinson bar (PCB: ACS-14T) and frequency response fotm 100 Hz to ±1 dB point (PCB: ACS-22T). See notes on calibration for additional information
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: 100-8994-40 - Coupling grease 100-8360-70 - STD mounting screw (1/4-28 x 1.5" long) (qty 2) Calibration - NIST traceable and ISO 17025/A2LA accredited calibration for high G shock using Hopkinson bar (PCB: ACS-14T) and frequency response fotm 100 Hz to ±1 dB point (PCB: ACS-22T). See notes on calibration for additional information
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
Rental Includes: 100-16040-40 - Metric mounting screws (M6x1.0 x 22mm long 100-8994-40 - Coupling grease 100-8360-70 - STD mounting screw (1/4-28 x 1.5" long) (qty 2) Calibration - NIST traceable and ISO 17025/A2LA accredited calibration for high G shock using Hopkinson bar (PCB: ACS-14T) and frequency response fotm 100 Hz to ±1 dB point (PCB: ACS-22T). See notes on calibration for additional information
5-ft integral cable terminating in 1/4-28 4-pin jack used with 010G, 034G, or 078G series cable
/NC (No Cable) option available-use your own or choose custom length and configuration here.
Rental Includes: Calibraton - NIST traceable and ISO 17025/A2LA accredited calibration from at least 5 Hz to 100 Hz (TMS: 5 Hz to 1000 Hz, MCS-A001 or PCB: 0.5 Hz to 100 Hz, ACS-17).
Note: Used in whole body vibration and vehicle operation tests; meets ISO 10326-1 standard.
Calibration data is provided electronically (on CD or USB memory stick) or as printed copies, depending on quantity rented and end-user preference.
The Modal Shop has internal calibration intervals set for most test products at 1 year. ANSI/ISO/IEC 17025:2000 makes clear that it is the responsibility of the end-user organization (in this case, the renter) to determine the appropriate calibration interval under the requirements of its own quality system. Per this, calibration certificates of rented equipment have "calibrated on" dates, but blank "calibration due" dates. Rentals ship with a customer specific expected return date in mind - if equipment is expected out for 5 months, the last calibration date will be within the past 7 months. Calibration to additional standards (e.g. Z540 or specific FAA requirements) are possible, but there may be an additional charge.
The Modal Shop's Scope of Accreditation can be found here. An example of a calibrations certificate can be found here. Please contact us with questions or if a different calibration will be needed for your rental sensors.
Notes on TEDS (Transducer Electronic Data Sheet) Back to Top
The TEDS option is available on several rental transducers. TEDS stands for Transducer Electronic Data Sheet and provides memory within a sensor with manufacturer name, sensor type, model number, serial number and calibration data. It is an approved IEEE standard (1451.4), and many data acquisition manufacturers include the ability to read TEDS sensors. Not sure if your DAQ has TEDS capability? No problem; TEDS sensors can be used alongside non-TEDS sensors with no issues; the TEDS memory is bypassed. Want more information? See our TEDS FAQ.