9155D Accelerometer Calibration WorkstationTurnkey Model 9155Quick Links: Video Tutorial, Optional Additions, Basic Specs, Included Accessories
PCB is the world leader in piezoelectric and measurement grade MEMS accelerometers. Users from the world's largest aerospace companies and the major automotive manufacturers, to research labs and consumers projects - have confidence in us with their accurate and high throughput calibration needs. TMS offers precise, elegant and efficient automated accelerometer calibration, providing metrology control and confidence.
The Accelerometer Calibration Workstation Model 9155 offers accurate back-to-back comparison calibrations of ICP® (IEPE) and charge mode piezoelectric accelerometers in accordance with ISO 16063-21. The 9155 system also calibrates piezoresistive (MEMS), capacitive, and velocity sensors via available options. Benefits of the Model 9155 form in two areas: conformance to existing standards and automation of the calibration task.
- Proven - Global recognition as market leader
- Accurate - Ensures traceable calibrations to NIST and PTB
- Simple - Turnkey system includes all necessary components
- Fast - Calibration typically performed in under a minute per axis
- Familiar - Windows PC supplies intuitive user interface
- Versatile - Define multiple pass/fail criteria for each test and automatically recall them from the internal database
- Customized - Prints customizable ISO 17025 compliant certificates
- Automatic - Set-up tests, acquire data, save results and print reports with ease, precision and automation
Loading the player...
Video describing the basic operation of our accelerometer calibration system.
Optional Additions to 9155
Configurations offer automated TEDS sensor updating, linearity check, low frequency calibration down to 0.1 Hz, shock calibration and a host of shaker options.
Basic 9155 System Specifications
Frequency Range |
5 Hz - 2 kHz with 9155D-875 High Payload Shaker Option |
|
5 Hz - 15 kHz with 9155D-830 Air-Bearing Shaker Option |
|
5 Hz - 20 kHz with 9155D-831 Air-Bearing Shaker Option |
|
0.5 Hz - 100 Hz with 9155D-771 Low Frequency Shaker Option |
|
0.1 Hz - 100 Hz with 9155D-779 Low Frequency Shaker Option |
|
Shaker Options are modular and may be combined in a single system to provide the most extended frequency range |
Typical Measurement Uncertainty1, 2 |
1.70% (5-9 Hz) |
|
1.20% (10-99 Hz) |
|
0.75% (100 Hz) |
|
1.00% (101 - 920 Hz) |
|
1.40% (921 - 5,000 Hz) |
|
1.90% (5,001 - 10,000 Hz) |
|
2.20% (10,001-15,000 Hz) |
|
2.80% (15,001-20,000 Hz) |
Calibration Method |
Applicable standards per ISO 16063, IEC 61094-5 ANSI B88.1 as appropriate |
Measurements |
Sensitivity, Amplitude, Phase, Bias, Resonance5, Linearity5, Shock5, Shunt5, DC Offset, Bridge Resistance, DC Sensitivity |
Operation Types |
ICP®, Charge, Voltage, Capacitive3, Piezoresistive4, CVLD, 4-20 mA Current Loop, Visual Output Sensors (aka meters) |
Sensor Types |
Vibration Acceleration, Shock Acceleration, Acoustic Microphones, Dynamic Pressure |
TEDS Sensor Support |
IEEE 1451.45, IEEE P1451.45, Siemens LMS formats5 |
Excitation Type |
Stepped Sine, Multi-sine |
Calibration Data Management |
Yes |
Automatic pass/fail Classification |
Yes |
Measurement Units |
English, Metric |
Input Power |
100-120V or 220-240V at 48 to 62 Hz |
Calibration Run Time |
<90 seconds7 |
1 Random component estimates significantly affected by shaker selection and environmental conditions
2 Best measurement uncertainty available with recalibration of reference sensors via primary standards
3 Capacitive sensors supported in base s/w. Capacitive sensor signal conditioning available as 9155D-445 option
4 Piezoresistive sensors supported in base s/w. Signal conditioning available as 9155D-478 option
5 Optional features
6 Shaker dependent, limited by stroke and load capacity
7 10 Hz to 20 kHz at 1/3 octaves
Accessories Included
- PC with Printer
- 9155 Calibration Software (see Software Features)
- Data Acquisition Hardware
- Database Software
- System Verification Sensor
- Various Mounting Adaptors and Cables
- Uncertainty Budget Procedures
- On-Site Installation and Training
Return to Calibration Home page
|