Transducer Calibration Services

Vibration | Shock | Acoustics | Electronics

Choose The Modal Shop as your partner in an accurate, controlled and confident transducer calibration program. Please refer to our  Scope of Accreditation for TMS A2LA accredited service scope and uncertainties.

Simply email  info@modalshop.com or call 800.860.4867 (toll free domestic) or +1.513.351.9919 (international) to arrange a return material authorization (RMA) number and include this number on your incoming package and paperwork.

Calibration Services

The following services ensure accurate data and provide a calibration certificate.


Accelerometers

Calibration Service Codes

CodeRange of CalibrationNISTA2LADescription
MCS‑A001‑A0040.5 Hz to upper 5% frequencyxxSingle axis accelerometer, amplitude and phase response
MCS‑A001‑A004T0.5 Hz to upper 5% frequencyxxTriaxial accelerometer, amplitude and phase response
MCS‑A0105 Hz to 10 kHzxxSystem calibration for calibration standard system
MCS-A0135 Hz to 10 kHzxxSystem calibration for calibration standard system w/ data on disk (for TMS 9155 and 9150D)
MCS‑355 Hz to 20 kHzxxSingle axis high frequency amplitude and phase response calibration. Includes sensor bias measurement (for ICP® sensors) and resonant frequency sweep up to 50 kHz
MCS‑35T5 Hz to 20 kHzxxTriaxial high frequency amplitude and phase response calibration. Includes sensor bias measurement (for ICP® sensors) and resonant sweep up to 50kHz
MCS‑A0015 Hz to upper 5% frequencyxxCalibration of accelerometer, single axis amplitude and phase response
MCS‑A001T5 Hz to upper 5% frequencyxxCalibration of accelerometer, triaxial amplitude and phase response
MCS‑A0655 Hz to 20 kHz
xPrimary accelerometer calibration service, using laser interferometry per ISO 16063-11. Up to 45 specific, user defined frequencies.
MCS‑A067100 Hz
xSingle point primary accelerometer calibration via laser interferometer
MCS‑31max 10,000gxxHigh g accelerometer calibration using PneuShockTM at 5 amplitudes
MCS‑31Tmax 10,000gxxHigh g accelerometer calibration for triaxial sensor using PneuShockTM

Microphone and Acoustic Calibration Service Codes

Popular Services

CodeDescriptionPrice
Standard Precision Condenser Microphones and Related Preamplifiers
MCS-9Calibration of precision microphone/preamplifier pair per IEC 61094-6 Electrostatic Actuator, NIST traceable. A2LA accredited. TEDS updated if enabled.

 

Most common calibration. Open circuit sensitivity measured at 251.2 Hz, using the insert voltage method. Frequency response measured from 20 Hz up to 95 kHz or the upper ±2 dB range spec, whichever is lower. This calibration code is used for 1/2", 1/4" and 1" condenser microphones with a removeable grid cap. Quantity discounts available.
$224
MCS-9-SPCalibration of precision microphone/preamplifier pair per IEC 61094-6 Electrostatic Actuator, Frequency range and test details described in Calibration Requests. NIST traceable. A2LA accredited. TEDS updated if enabled.

 

Similar to MCS-9 but can be used if a custom frequency range beyond upper ±2 dB spec is requested.
 contact
MCS-2Calibration of standard precision condenser microphones, NIST traceable. A2LA accredited.

 

Similar calibration to MCS-9, but for microphone capsule only
$164
MCS-6Certification of precision microphone preamplifiers, NIST traceable.

 

Includes preamplifier PCB 426E01, but no microphone included with this calibration. Generally, units are calibrated as a pair to provide best results. 
$164
Array Microphones, Microphones without Removeable Gridcaps
MCS-70Calibration of microphone/preamplifier pair per IEC 61094-5 Comparison Calibration, NIST traceable. A2LA accredited.

 

Calibration for microphones without removable grid caps, including array and ruggedized microphones. Frequency response measured from 20 Hz up to 20 kHz. This calibration code is used for 1/2" and 1/4" microphones. Quantity discounts available.
$210
MCS-1Calibration of array microphone and preamplifier pair, NIST traceable.

 

Similar method to MCS-xxx, but non A2LA accredited. Ideal for array microphones such as PCB 130 Series. Quantity discounts available.
$119
Specialty Microphones and Acoustic Accessories
ACS-46Calibration of Probe Microphone, back to back reference. 

 

Includes models PCB 377B26, B&K 4182, GRAS 40SA and 40SC. Calibration performed by PCB Piezotronics.
$283
ACS-156Calibration of microphone/preamplifier pair per IEC 61094-8 Comparison Calibration, NIST traceable. A2LA accredited.

 

Comparison method available for microphones or microphone/preamplifier pairs, performed in an anechoic chamber. Generally used for low noise microphone systems such as PCB 378A04) where an actuator would influence the acoustic impedance of the microphone. Can also be used for non-condenser microphones and other microphones without a removable grid cap. System sensitivity is reported at 1000 Hz, frequency response reported from 200 Hz to 20 kHz, with typical low frequency response noted. Calibration performed by PCB Piezotronics.
$267
MCS-3Calibration of phase matched microphone pair, NIST traceable.$633
MCS-14Calibration of In-Line A-Weighting Filter.

 

Includes PCB models 426B02 and 426A02
$117
Handheld Acoustic Calibrators (Speakerphones, Pistonphones)
MCS-56Calibration of speakerphone sound level calibrator, NIST traceable. A2LA accredited.

 

Including Larson Davis CAL150, CAL200, CAL250, CAL1150, CAL1200, CAL1250, B&K Type 4231, GRAS 42AG and Norsonic Nor-1251
$170
MCS-4 Calibration of pistonphone, NIST traceable. A2LA accredited.

 

Including PCB 394A40, GRAS 42AA, 42AC and 42AP, and B&K 4228 
$266
Calibration / Verification of TMS Acoustic Calibration Products

 

Verification microphones are not included in these calibration codes. Verification microphones are used to perform a system stability check, and are run at the start of each day when using the calibration system to verify system performance. Comparing verification microphone results over time will catch many issues with the system ranging from unexpected electronic issues to damaged hardware. If a verification microphone is suspected to be damaged or a calibration is still needed, select an appropriate code (typically MCS-9) above.
MCS-27Recalibration of reference microphone for 9350C system, NIST traceable. A2LA accredited.$306
9155D-C919-1/2Reference Calibration Service for TMS Model 9919C. Calibration of 1/2 inch 9919 reference microphone top with paired signal conditioner. 20 Hz to 20 kHz Frequency Range. Requires return of complete top reference fixture. Includes data on disk.$540
9155D-C919-1/4Reference Calibration Service for TMS Model 9919C. Calibration of 1/4 inch 9919 reference microphone top with paired signal conditioner. 20 Hz to 20 kHz Frequency Range. Requires return of complete top reference fixture. Includes data on disk.$540
K9000-C917SCalibration service on Model K9000-917 series. Includes recalibration of 9000A, 9917C and Reference Microphone components, as well as upload of reference sensor data to 9000A, updated 9000A report generation workbook, factory acceptance test, and any firmware updates applicable to system components.$1,730
Other Acoustic Items / Referrals
Sound Level MetersLarson Davis offers an accredited calibration service of their meters, and can service their current product line. TMS does not offer calibration of sound meters at this time. 
DosimetersSimilarly, Larson Davis offers accredited calibration of dosimeters, TMS does not. 
HydrophonesAlthough TMS rents hydrophones that can be point checked with a pistonphone and appropriate adaptor, we do not offer calibration service for hydrophones at this time. Contact the manufacturer. 
Acoustic SourcesTMS rents acoustic sources and various Building Acoustics test equipment, but we do not calibrate internally. In general, Riverbank Acoustical Laboratories calibrates these products for us. 

Handheld and Portable Calibrators

CodeNISTA2LADescription
MCS‑A009x
Calibration of handheld calibrator, models 394C05, 394B06, and 394C06 or similar
9100‑CAL01xxCalibration of 9100 Series Portable Vibration Calibrator
9200-CAL01x Calibration of 9200 Series Low Frequency Portable Vibration Calibrator

Electronics

Calibration Service Codes

CodeDescription
MCS-E001Calibration of 422 series in-line charge amplifier, NIST traceable.
MCS-19Recalibration of LanSharc SDC003, NIST traceable.
MCS-21Recalibration of VibeAlarm SDC002, NIST traceable.
MCS-36TEDS sensor programming using 400B76 utility software.
MCS-41Calibration of 422 series in-line charge amplifier including 422M184. NIST traceable, A2LA accredited.
MCS‑A047Calibration of USB signal conditioner 485B36 2 channel and equivalent, NIST traceable.
MCS‑E003Calibration of 480 series (480C, 480C02, 480D, & 480D02), model 478A01, and equivalent models, NIST traceable. A2LA accredited.
MCS‑E004Calibration of 480 series (480E06, 480E09, 480D06, & 480D09) and equivalent with multiple gain x1, x10, x100, NIST traceable. A2LA accredited.
MCS‑E005Calibration of models 482A, 482A06/B06, 482A05/B05, 482A04, 482A21, 482A22, and equivalent, NIST traceable. A2LA accredited.
MCS‑E010Calibration of series 481, models 533, 583, 584, 478A16, 478A17 & other various 16-channel signal conditioner, NIST traceable. A2LA accredited.
MCS‑22Calibration Service for National Reliability VB Analyzers
ERC‑1Standard Recalibration 422E series in-line Charge Amplifier. A2LA accredited.

Impulse Hammers and Force Sensors

Calibration Service Codes

CodeNISTA2LADescription
MCS‑H005xxCalibration of 086 series instrumented hammer or similar, Includes data for up to six tips and one extender mass if provided
MCS‑H003xxCalibration of 288 series Impedance Head