Transducer Calibration Services

Vibration | Shock | Acoustics | Electronics

Choose The Modal Shop as your partner in an accurate, controlled and confident transducer calibration program. Please refer to our  Scope of Accreditation for TMS A2LA accredited service scope and uncertainties.

Simply email  info@modalshop.com or call 800.860.4867 (toll free domestic) or +1.513.351.9919 (international) to arrange a return material authorization (RMA) number and include this number on your incoming package and paperwork.

Calibration Services

The following services ensure accurate data and provide a calibration certificate.


Vibration Accelerometers

ModelDescription
MCS‑A001‑A004Calibration of accelerometer, single axis amplitude and phase response from 0.5 Hz to upper 5% frequency, NIST traceable. A2LA accredited.
MCS‑A001‑A004TCalibration of triaxial accelerometer, amplitude and phase response from 0.5 Hz to upper 5% frequency, NIST traceable. A2LA accredited.
MCS‑A010System calibration for calibration standard system. Frequency sweep from 5 Hz to 10 kHz, NIST traceable. A2LA accredited.
MCS‑35Single axis high frequency amplitude and phase response calibration from 5 Hz to 20 kHz. NIST traceable. A2LA accredited. Includes sensor bias measurement (for ICP® sensors) and resonant frequency sweep up to 50 kHz.
MCS‑35TTriaxial high frequency amplitude and phase response calibration from 5 Hz to 20 kHz, NIST traceable. A2LA Accredited. Includes sensor bias measurement (for ICP® sensors) and resonant sweep up to 50kHz.
MCS‑A001Calibration of accelerometer, single axis amplitude and phase response from 5 Hz to upper 5% frequency, NIST traceable. A2LA accredited.
MCS‑A001TCalibration of accelerometer, triaxial amplitude and phase response from 5 Hz to upper 5% frequency, NIST traceable. A2LA accredited.
MCS‑A065Primary accelerometer calibration service, using laser interferometry per ISO 16063-11 from 5 Hz to 20 kHz at up to 45 specific, user defined frequencies. A2LA accredited.
MCS‑A067Single point primary accelerometer calibration via laser interferometer at 100 Hz. A2LA accredited.



Shock Accelerometers

ModelDescription
MCS‑31High g accelerometer calibration using PneuShockTM to max 10,000g range at 5 amplitudes. NIST traceable. A2LA accredited.
MCS‑31THigh g accelerometer calibration for triaxial sensor using PneuShockTM to max 10,000g range. NIST traceable. A2LA accredited.
'

 


Microphones and Acoustic Instruments

ModelDescription
MCS‑1Calibration of 130 series array microphone and preamplifier pair, NIST traceable.
MCS‑2Calibration of standard precision condenser microphones, NIST traceable.A2LA accredited.
MCS‑6Certification of precision microphone preamplifiers, NIST traceable.
MCS‑9Calibration of precision microphone/preamplifier pair, NIST traceable. A2LA accredited.


Handheld and Portable Calibrators

ModelDescription
MCS‑A009Calibration of handheld calibrator, models 394C05, 394B06, and 394C06 or similar. NIST traceable.
9100‑CAL01Calibration of 9100 Series Portable Vibration Calibrator. NIST traceable.A2LA accredited.
MCS‑4Calibration of pistonphone, NIST traceable.
MCS‑56Calibration of speakerphone, NIST traceable.

 


Signal Conditioners and Electronics

ModelDescription
MCS‑A047Calibration of USB signal conditioner 485B36 2 channel and equivalent, NIST traceable.
MCS‑E003Calibration of 480 series (480C, 480C02, 480D, & 480D02), model 478A01, and equivalent models, NIST traceable. A2LA accredited.
MCS‑E004Calibration of 480 series (480E06, 480E09, 480D06, & 480D09) and equivalent with multiple gain x1, x10, x100, NIST traceable. A2LA accredited.
MCS‑E005Calibration of models 482A, 482A06/B06, 482A05/B05, 482A04, 482A21, 482A22, and equivalent, NIST traceable. A2LA accredited.
MCS‑E010Calibration of series 481, models 533, 583, 584, 478A16, 478A17 & other various 16-channel signal conditioner, NIST traceable. A2LA accredited.
MCS‑22Calibration Service for National Reliability VB Analyzers
ERC‑1Standard Recalibration 422E series in-line Charge Amplifier. A2LA accredited.

 


Impulse Hammers and Force Sensors

ModelDescription
MCS‑H002Calibration of 086 series instrumented hammer or similar, NIST traceable. A2LA accredited.
MCS‑H003Calibration of 288 series Impedance Head, NIST traceable. A2LA accredited.